▶CATALOG▶MANUAL Features•Able to measure both fluids and powders
•Two-wire type; reduction of installation cost •Corrosion-proof and chemical-proof PTFE material•The structure of the detection part is simple, Without a mobile part; optimal for sanitation facilities such as food and beverage •Selection of various detection part structure according to the temperature/pressure •Explosion proof type possible (Ex d ⅡB T4/Ex ia ⅡB T6)Specifications OUTPUT
POWER SUPPLY4∼20mA DC
24V DCTEMPERATURE•-20℃∼60℃PRESSUREAMB.RANGE•Standard
Rod type: 1m, Wire type: 5m
•Optional
Rod type: 4m, Wire type: 30mPRINCIPLEThe static capacity value, according to the dielectric constant change of the measured substance generated between the measured electrode and the earth electrode, is serially detected, and changed into an electric current signal of DC 4∼20mA to be put out. It is an all purpose meter controller that can measure fluids, powders, and interfaces.APPLICATION•PE, PP, PC, PVC powder tanks, etc.•two-liquid interface•etc.REMARKMat'l : 304/316SS (PTFE Tubing) 후로벨 2014.03.24
▶CATALOG▶MANUAL Features•Able to measure both fluids and powders
•Two-wire type; reduction of installation cost •Corrosion-proof and chemical-proof PTFE material•The structure of the detection part is simple, Without a mobile part; optimal for sanitation facilities such as food and beverage •Selection of various detection part structure according to the temperature/pressure •Explosion proof type possible (Ex d ⅡB T4/Ex ia ⅡB T6)Specifications OUTPUT
POWER SUPPLY4∼20mA DC
24V DCTEMPERATURE•-20℃∼60℃PRESSUREAMB.RANGE•Standard
Rod type: 1m, Wire type: 5m
•Optional
Rod type: 4m, Wire type: 30mPRINCIPLEThe static capacity value, according to the dielectric constant change of the measured substance generated between the measured electrode and the earth electrode, is serially detected, and changed into an electric current signal of DC 4∼20mA to be put out. It is an all purpose meter controller that can measure fluids, powders, and interfaces.APPLICATION•PE, PP, PC, PVC powder tanks, etc.•two-liquid interface•etc.REMARKMat'l : 304/316SS (PTFE Tubing) 후로벨 2014.03.24
2
VEGACAL 62
▶ CATALOG    (same as VEGACAL 65) ▶ You can get a MANUAL
    in Download tab▶ VEGACAL 62 is a level sensor for continuous level measurement in all areas of industry.
    Partly insulated probes such as VEGACAL 62 are preferably used in bulk solids.
    However, the probe can also be used in non-conductive liquids such as e.g. oil.
    Sensor and vessel form the two electrodes of a capacitor.
    A level change causes a capacitance change which is converted into a continuous output signal by the connected processing electronics.
Features - High reliability
- Simple mounting and setup
- Measurement along the complete probe length
- Probe can be shortened
Specifications Process fittingfrom G1½AProcess temperature-50 … +200 °CProcess pressure-1 … +64 bar
(-100 … +6400 kPa)Versionwith partly insulated rod Flovel 2010.09.10
▶ CATALOG    (same as VEGACAL 65) ▶ You can get a MANUAL
    in Download tab▶ VEGACAL 62 is a level sensor for continuous level measurement in all areas of industry.
    Partly insulated probes such as VEGACAL 62 are preferably used in bulk solids.
    However, the probe can also be used in non-conductive liquids such as e.g. oil.
    Sensor and vessel form the two electrodes of a capacitor.
    A level change causes a capacitance change which is converted into a continuous output signal by the connected processing electronics.
Features - High reliability
- Simple mounting and setup
- Measurement along the complete probe length
- Probe can be shortened
Specifications Process fittingfrom G1½AProcess temperature-50 … +200 °CProcess pressure-1 … +64 bar
(-100 … +6400 kPa)Versionwith partly insulated rod Flovel 2010.09.10
1
VEGACAL 65
▶ CATALOG    (same as VEGACAL 62) ▶ You can get a MANUAL
    in Download tab▶ VEGACAL 65 is a level sensor for continuous level measurement in all areas of industry.
    Partly insulated probes such as VEGACAL 65 are preferably used in bulk solids.
    However, the probe can also be used in non-conductive liquids such as e.g. oil.
    Sensor and vessel form the two electrodes of a capacitor.
    A level change causes a capacitance change which is converted into a continuous output signal by the connected processing electronics.
Features - High reliability
- Simple mounting and setup
- Measurement along the complete probe length
- Probe can be shortened
Specifications Process fittingfrom G1AProcess temperature-50 … +200 °CProcess pressure-1 … +64 bar
(-100 … +6400 kPa)Versionwith cable Flovel 2010.09.10
▶ CATALOG    (same as VEGACAL 62) ▶ You can get a MANUAL
    in Download tab▶ VEGACAL 65 is a level sensor for continuous level measurement in all areas of industry.
    Partly insulated probes such as VEGACAL 65 are preferably used in bulk solids.
    However, the probe can also be used in non-conductive liquids such as e.g. oil.
    Sensor and vessel form the two electrodes of a capacitor.
    A level change causes a capacitance change which is converted into a continuous output signal by the connected processing electronics.
Features - High reliability
- Simple mounting and setup
- Measurement along the complete probe length
- Probe can be shortened
Specifications Process fittingfrom G1AProcess temperature-50 … +200 °CProcess pressure-1 … +64 bar
(-100 … +6400 kPa)Versionwith cable Flovel 2010.09.10