MY MENU
제목

SCAP-IV

작성자
후로벨
작성일
2014.03.24
첨부파일0
추천수
0
조회수
660
내용


CATALOG

MANUAL

Features

•Able to measure both fluids and powders
•Two-wire type; reduction of installation cost 
•Corrosion-proof and chemical-proof PTFE material
•The structure of the detection part is simple, Without a mobile part; optimal for
 sanitation facilities such as food and beverage 
•Selection of various detection part structure according to the temperature/pressure 
•Explosion proof type possible (Ex d ⅡB T4/Ex ia ⅡB T6)

Specifications 

OUTPUT
POWER SUPPLY
4∼20mA DC
24V DC
TEMPERATURE•-20℃∼60℃
PRESSUREAMB.
RANGE•Standard
 Rod type: 1m, Wire type: 5m
•Optional
 Rod type: 4m, Wire type: 30m
PRINCIPLEThe static capacity value, according to the dielectric constant change of the measured substance generated between the measured electrode and the earth electrode, is serially detected, and changed into an electric current signal of DC 4∼20mA to be put out. It is an all purpose meter controller that can measure fluids, powders, and interfaces.
APPLICATION•PE, PP, PC, PVC powder tanks, etc.
•two-liquid interface
•etc.
REMARKMat'l : 304/316SS (PTFE Tubing)