Capacitance Type LS
1
SCAP
▶CATAOG▶MANUAL
Features•Successful task jointly performed with the Korea Research Institute of standards •Applicable to fluids, powders & fine powders •The materials and format of the detecting part can be selected according to the various measured substances •The attached substances' static power generator (substance) measurable•Automatic control function embedded •Explosion proof type possible (Ex d ⅡB T4)Specifications OUTPUT
POWER SUPPLY•1 DPDT
•Contact capacity : 5A 250V AC
110/220V AC, 50/60HzTEMPERATURE•Standard : -20℃∼80℃
•Optional : -20℃∼230℃PRESSURE AMB. RANGE•Standard : 250mm
•Optional : Rod Type - within 500mm
Wire Type : Within 5000mm PRINCIPLEWhen the measured substance with a consistent relative dielectric constant fills up between the metal type tank connected to the earth pole and the measured pole, the device detects the changed static capacity value(C) between the measured pole and the earth pole. It was designed to automatically calibrate with just one adjustment, regardless of the relatively dielectric constant.
-Obtained the EM Mark of the
Technology Standard Office. APPLICATION•Water, Oil, Chemical substance, Paint, Sludge tank•Measurement of the water and oil's interface •Cement, Sugar, Barley, Grains, Resin, Resin Powder, Chip, Ore, Coal, Slaked lime silo, etc.REMARKMat'l : 304/316SS (PTFE Tubing) 후로벨 2014.03.24
▶CATAOG▶MANUAL
Features•Successful task jointly performed with the Korea Research Institute of standards •Applicable to fluids, powders & fine powders •The materials and format of the detecting part can be selected according to the various measured substances •The attached substances' static power generator (substance) measurable•Automatic control function embedded •Explosion proof type possible (Ex d ⅡB T4)Specifications OUTPUT
POWER SUPPLY•1 DPDT
•Contact capacity : 5A 250V AC
110/220V AC, 50/60HzTEMPERATURE•Standard : -20℃∼80℃
•Optional : -20℃∼230℃PRESSURE AMB. RANGE•Standard : 250mm
•Optional : Rod Type - within 500mm
Wire Type : Within 5000mm PRINCIPLEWhen the measured substance with a consistent relative dielectric constant fills up between the metal type tank connected to the earth pole and the measured pole, the device detects the changed static capacity value(C) between the measured pole and the earth pole. It was designed to automatically calibrate with just one adjustment, regardless of the relatively dielectric constant.
-Obtained the EM Mark of the
Technology Standard Office. APPLICATION•Water, Oil, Chemical substance, Paint, Sludge tank•Measurement of the water and oil's interface •Cement, Sugar, Barley, Grains, Resin, Resin Powder, Chip, Ore, Coal, Slaked lime silo, etc.REMARKMat'l : 304/316SS (PTFE Tubing) 후로벨 2014.03.24